NPS62-M Emerson Network Power, NPS62-M Datasheet

POWER SUP MED&ITE 5V 60W 2"X4"

NPS62-M

Manufacturer Part Number
NPS62-M
Description
POWER SUP MED&ITE 5V 60W 2"X4"
Manufacturer
Emerson Network Power
Series
NPS60-Mr
Datasheet

Specifications of NPS62-M

Operating Temperature
0°C ~ 50°C
Power (watts) - Rated
60W
Efficiency
87%
Approvals
CE, CB, CQC, CSA, NEMKO, TUV, UL
Line Regulation
2%
Load Regulation
2%
Voltage - Output
5V
Number Of Outputs
1
Power (watts)
60W
Applications
Medical
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 12A
Size / Dimension
4.00" L x 2.00" W x 1.00" H (101.6mm x 50.8mm x 21.8mm)
Product
Switching
Commercial/medical
Both
Output Power Rating
60 W
Input Voltage
90 VAC to 264 VAC
Output Voltage (channel 1)
5 V
Mounting Style
Chassis
Dimensions
4 in L x 2 in W x 1 in H
Open Frame/enclosed
Open Frame
Power Supply Output Type
Fixed
No. Of Outputs
1
Input Frequency
440Hz
Output Voltage
5V
Output Current
12A
Power Rating
60W
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2nd Output
-
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1421
NPS63-M Series
60 Watts
Total Power:
Input Voltage:
# of Outputs:
Special Features
• Medical and ITE Safety Approvals
• Universal input
• Less than 1U high
• 2” x 4” footprint
• Remote sense
• Overload and short circuit
• Adjustable output voltage
• High efficiency
• High MTBF
• Built in EMI filter
• International Efficiency Level V,
• Less than 300 mW no-load
• 0˚C to +80˚C operation
• Input power < 74 watts
• Complies with EN61000 -3-2
• UL Class I approved
• Class II approved (with Class A
• LPX50 enclosure kit available
• Dual AC fuses
Safety
• TUV: 60950, 60601-1
• UL:
• CSA: 60950, 60601-1
• NEMKO: 60950, 60601-1
• CB:
• CE:
protection
(CISPR 22 Class B)
Energy Star 2.0 & CeC compliant
(except NPS62-M)
power consumption
EMI)
60950, 60601-1
Mark (LVD)
Certificate and report
60 Watts
90 - 264 VAC
127 - 300 VDC
Single
Input
Input ra n ge:
Frequency:
Inrush current:
Input power:
Efficiency:
EMI/RFI:
Safety ground leakage
current:
Output
Maximum power:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection: 30-50% above nominal output
Remote sense:
Electrical Specifications
90 - 264 VAC (wide range) 127-300 Vdc
47-63 Hz
< 50 A peak @ 230 VAC, cold start @ 25° C
< 74 Watts
87% average (as per Energy Star 2.0 standard) (NPS62-M, 80%)
FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B con-
ducted, VDE0878PT3 Class B conducted
275uA @ 50/60 Hz; 264 VAC input
60 W for convection
± 20% minimum
10/ 2 0 ms 115/230 VAC input line
Short circuit protection on all outputs. Case overload protected @
110-160% of normal rating
Compensated for 0.5 V lead drop max. Will operate without remote sense
connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev.12.7.10_184
NPS63-M Series
1 of 3

Related parts for NPS62-M

NPS62-M Summary of contents

Page 1

... Electrical Specifications Input Input 264 VAC (wide range) 127-300 Vdc Frequency: 47-63 Hz Inrush current: < peak @ 230 VAC, cold start @ 25° C Input power: < 74 Watts Efficiency: 87% average (as per Energy Star 2.0 standard) (NPS62-M, 80%) EMI/RFI: FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B con- ducted, VDE0878PT3 Class B conducted Safety ground leakage 275uA @ 50/60 Hz; 264 VAC input current: Output Maximum power for convection Adjustment range: ± ...

Page 2

Environmental Specifications 0° °C ambient derate each output at 2.5% per degree from 50° °C. -20 °C start up Operating temperature: Storage temperature: -45 °C to +85 °C Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 10% to 90% RH Vibration: IEC68-2-6 to the levels of IEC721-3-2 MTBF demonstrated: > 550,000 hours at full load and 25 °C ambient conditions Mechanical Drawing Embedded Power for Business-Critical Continuity Rev.12.7.10_184 NPS63-M Series ...

Page 3

... Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.Emerson.com/EmbeddedPower techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & ...