Specifications
AC Input
Input Current
Inrush Current
Input Fuse
Efficiency
Output Voltage
Output Power
Ripple and Noise
Line & Load Voltage Regulation
Minimum Load
Case Material
Case Dimensions
Weight
Conducted Emissions
Radiated Emissions
Line Frequency Harmonics
Voltage Fluctuations/Flicker
Static Discharge Immunity
Radiated RF Immunity
EFT/Burst Immunity
Line Surge Immunity
Conducted RF Immunity
Power Frequency Magnetic Field Immunity
Voltage Dip Immunity
CENB1010
Universal 10 Watt Series
ITE Switch-Mode Power Supply
•
•
•
•
•
•
•
•
•
•
100-240VAC Universal Input Range
Meets EISA2007, CEC Efficiency Level V,
Desktop & Wall Plug Styles
5V to 48V Single Output Models, up to 12W
Modified and Custom Designs Available
Regulated Output with Low Ripple
Impact-Resistant Polycarbonate Enclosure
No load Power Consumption <0.3W
Limited Power Source
Certified to UL/EN/IEC60950-1, 2
EU (EC) No 278/2009 Phase II
________________________________________________________________________________________________________________________________
SL Power Electronics Corp
Internal Primary Current Fuse provided (1A, 250Vac rated)
Meets EISA2007, CEC Efficiency Level V,
RoHS
•
6050 King Drive Ventura, CA 93003
84 x 47 x 32mm. See outline drawing
100-240VAC, -/-10%, 47-63 Hz, 1∅
EU (EC) No 278/2009 Phase II
nd
1% pk-pk max., 20MHz BW
Black 94V-0 Polycarbonate
60 A peak max at 264 Vac
Line: +/- 1%, Load: +/-5%
Edition
100Vac: 0.27A
Not required
All Specifications are typical at nominal input, full load at 25
EMC Specifications
See chart
See chart
•
110g
Phone 805.486.4565 • Fax 858.712.2040
LPS
LPS
LPS
LPS
MTBF
Hold-up Time
Overload Protection
Short Circuit Protection
Topology
Safety Standards
EMC, Radiated & Conducted
Dielectric Withstand
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
Output Cable
Output Connector
EN55022 Class B, FCC Part 15, Class B.
EN55022 Class B, FCC Part 15, Class B.
EN61000-3-2, Class A
EN61000-3-3
EN61000-4-2, 6kV Contact Discharge, 8kV air discharge
EN61000-4-3, 3V/m.
EN61000-4-4, 2kV/5kHz.
EN61000-4-5, 1kV differential, 2kV common-mode
EN61000-4-6, 3Vrms
EN61000-4-8, 3A/m
EN61000-4-11, Criteria B
3 Year Warranty
Other options available, contact the factory for details
Input-Ground: 1,500 Vac, Output-Ground: 500 Vdc
•
Email: info@slpower.com
2.5mm barrel type (Ault #3), center contact (+)
18 ms min. @ 115Vac, 60 ms min. @ 230 Vac
#20AWG (UL2468), 1500mm, 2 conductor
EN/IEC/CSA/UL60950-1, 2
Switching – Fixed Frequency Flyback
°
C unless otherwise stated.
5% to 95%, non-condensing
>100,000 hours (calculated)
Input-Output: 4,242Vdc,
•
0° to 40°C, no derating
www.slpower.com
See Chart below
nd
0 to 10,000 ft
Hiccup Mode
Hiccup Mode
Edition, LPS
-30 to +85°C
1 of 2