G6L-1P-DC12 Omron, G6L-1P-DC12 Datasheet
G6L-1P-DC12
Specifications of G6L-1P-DC12
Available stocks
Related parts for G6L-1P-DC12
G6L-1P-DC12 Summary of contents
Page 1
... Example: G6L-1P DC12 Rated coil voltage 2. When ordering tape packing (surface mount versions), add "-TR" to the model number. Example: G6L-1F-TR DC12 Tape packing Be sure since "-TR" is not part of the relay model number not marked on the relay case. Model Number Legend: ...
Page 2
... Voltage Rating 4.5 VDC 5 VDC 40.0 mA 36.0 mA 112.5 Ω 139.0 Ω G6L-1P, G6L-1F 100 mΩ max max. (approx. 1.1 ms max. (approx. 0.4 ms) 1,000 MΩ min. (at 500 VDC) 1,000 VAC, 50/60 Hz for 1 min 750 VAC, 50/60 Hz for 1 min 1,500 VAC, 10 × 160 μ Hz, 1 ...
Page 3
... Relays to check the number of contact malfunctions. Contact Reliability Test (Contact Resistance) (See notes 1 and 2) 1,000 Sample: G6L-1F NO contact Number of Relays: 10 Test conditions: 1-A resistive load at 500 24-VDC with an operation rate of 50% Switching frequency: 1,800 operations/h 300 max ...
Page 4
... Installed in flush configuration Must operate voltage Must release voltage (Average value) + +20 +10 0 −10 −20 Must operate voltage Sample: G6L-1F Must release voltage Number of Relays: 5 −30 −1,200 −800 −400 0 400 800 1,200 External magnetic field (A/m) High-frequency Characteristics (Return Loss, V.SWR) (See note) ...
Page 5
... Must Operate and Must Release Time Distribution (See Note) 40 Sample: G6L-1F Must operate time Number of Relays: 50 Must release time 0.5 1 1.5 2 2.5 3 Time (ms) Note: The tests were conducted at an ambient temperature of 23°C. Dimensions Note: All units are in millimeters unless otherwise indicated. ...
Page 6
... Top tape (cover tape) Carrier tape Embossed tape 2. Reel Dimensions 25.5 ±0.5 29.5 ± 330 Enlarged View of Section A G6L 42 Low Signal Relay Stopper (green) 3. Carrier Tape Dimensions G6L-1F Orientation mark 4 ±0.1 2 ±0.1 Pulling direction 12 ±0.1 13 dia. ±0.2 21 dia. ±0.5 ±0.5 R1 4.6 ±0 ...
Page 7
... Approved Standards UL Recognized (File No. E41515) / CSA Certified (File No. LR31928 Ambient Temp. = 40°C Contact form SPST-NO G6L-1P and G6L-1F VDC The thickness of cream solder to be applied should be within a range between 150 and 200 μm on OMRON's recommended PCB pattern. Correct Soldering Relay ...
Page 8
... Relay. Environmental Conditions During Operation, Storage, and Transportation Protect the Relays from direct sunlight and keep the Relays under normal temperature, humidity, and pressure. G6L 44 Low Signal Relay Maximum Voltage The maximum voltage of the coil can be obtained from the coil tem- perature increase and the heat-resisting temperature of coil insulat- ing sheath material ...
Page 9
... Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. Low Signal Relay G6L ...
Page 10
... E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 03/10 Cat. No. X301-E-1a G6L Low Signal Relay 2. Programmable Products. Seller shall not be responsible for the user's pro- gramming of a programmable product, or any consequence thereof. 3. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a war- ranty ...