Page 1
... Applications: £ AC Motor Control £ UPS £ Battery Powered Supplies Ordering Information: Example: Select the complete part module number you de- sire from the table below -i.e. CM600DY-24A is a 1200V (V ), CES 600 Ampere Dual IGBTMOD™ Power Module Type Current Rating V CES ...
Page 2
... GE C res t d(on 600V 600A 15V, R d(off) GE1 GE2 t Inductive Load f t Switching Operation 600A does not exceed T j Symbol CM600DY-24A T –40 to 150 j T –40 to 125 stg V 1200 CES V ±20 GES I 600 C I 1200 600 E I 1200 3670 C — 40 — 40 — ...
Page 3
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 CM600DY-24A Dual IGBTMOD™ A-Series Module 600 Amperes/1200 Volts Thermal and Mechanical Characteristics, T Characteristics Thermal Resistance, Junction to Case* Thermal Resistance, Junction to Case* Contact Thermal Resistance External Gate Resistance * measured point is just under the chips. ...
Page 4
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 CM600DY-24A Dual IGBTMOD™ A-Series Module 600 Amperes/1200 Volts REVERSE RECOVERY CHARACTERISTICS (TYPICAL 600V 15V 0.52Ω 25°C j Inductive Load EMITTER CURRENT (AMPERES) E SWITCHING LOSS VS. GATE RESISTANCE (TYPICAL 600V 15V 600A ...