2873.000.00 FEIG Electronic, 2873.000.00 Datasheet

ID CPR.M02 VP/AB-CA READER MOD

2873.000.00

Manufacturer Part Number
2873.000.00
Description
ID CPR.M02 VP/AB-CA READER MOD
Manufacturer
FEIG Electronic
Series
OBID® Classic-pro HF CPR.M02.VP/AB-BA/-CAr
Datasheet

Specifications of 2873.000.00

Rf Type
Read / Write
Frequency
13.56MHz
Features
ISO14443-A, ISO14443-B, ISO15693
Package / Case
50mm x 50mm x 14mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2873.000.00.00
629-1057
final
public (B)
2007-01-26
M21001-3de-ID-B.doc
OBID
®
classic-pro
ID CPR.M02
ID CPR.M02.VP/AB-BA
ID CPR.M02.VP/AB-CA
ID CPR.M02.VP/AB-B
ID CPR.M02.VP/AB-C
(deutsch / english)
INSTALLATION
MONTAGE

Related parts for 2873.000.00

2873.000.00 Summary of contents

Page 1

OBID classic-pro final public (B) 2007-01-26 M21001-3de-ID-B.doc ID CPR.M02 ID CPR.M02.VP/AB-B ID CPR.M02.VP/AB-BA ID CPR.M02.VP/AB-C ID CPR.M02.VP/AB-CA (deutsch / english) MONTAGE INSTALLATION ...

Page 2

... OBID classic-pro FEIG ELECTRONIC GmbH Montage Seite 2 von 42 ID CPR.M02 M21001-3de-ID-B.doc ...

Page 3

... OBID classic-pro deutsche Version ab Seite 4 english version from page 24 FEIG ELECTRONIC GmbH Montage Seite 3 von 42 ID CPR.M02 M21001-3de-ID-B.doc ...

Page 4

... Hinweise jederzeit dankbar. Die in diesem Dokument gemachten Installationsempfehlungen gehen von günstigsten Rahmenbedingun- gen aus. FEIG ELECTRONIC GmbH übernimmt keine Gewähr für die einwandfreie Funktion in systemfrem- den Umgebungen. FEIG ELECTRONIC GmbH übernimmt keine Gewährleistung dafür, dass die in diesem Dokument enthal- tenden Informationen frei von fremden Schutzrechten sind ...

Page 5

... Nachgleich der integrierten Antenne (nur ID CPR.M02.VP/AB-B / -C)........................17 3.5. Montagehinweise ..............................................................................................................19 3.5.1. Metallische Umgebung ................................................................................................19 3.5.2. EMV-Beeinflussung über Zuleitungen .........................................................................19 3.5.3. EMV-Beeinflussung über magnetische Felder ............................................................20 4. Funkzulassungen 4.1. Europa (CE)........................................................................................................................21 4.2. USA (FCC) ..........................................................................................................................21 5. Technische Daten FEIG ELECTRONIC GmbH Montage Inhalt Seite 5 von 42 ID CPR.M02 M21001-3de-ID-B ...

Page 6

... Alle Arbeiten am Gerät und dessen Aufstellung müssen in Übereinstimmung mit den nationa- len elektrischen Bestimmungen und den örtlichen Vorschriften durchgeführt werden. • Beim Arbeiten an dem Gerät müssen die jeweils gültigen Sicherheitsvorschriften beachtet werden. FEIG ELECTRONIC GmbH Montage Seite 6 von 42 ID CPR.M02 M21001-3de-ID-B.doc ...

Page 7

... Leiterplattenantenne, 50Ω, 40mm x 30mm 2.3. Lieferumfang Folgende Komponenten sind im Lieferumfang enthalten: Modultyp ID CPR.M02 Readermodul ID CPR.M02-B ID CPR.M02- Readermodul ID CPR.M02-BA ID CPR.M02 Readermodul ID CPR.M02-C ID CPR.M02- Readermodul ID CPR.M02-CA FEIG ELECTRONIC GmbH Montage RS232-TTL Antenne Interface 4.800, 9.600, intern 19.200, 38.400 extern Baud 4.800, 9.600, intern 19 ...

Page 8

... Die Stiftleiste X2 zum Anschluss einer externen Antennen ist nur bei Modulen vom Typ ID CPR.M02.VP/AB-BA und ID CPR.M02.VP/AB-CA bestückt. • Der Trimmkondensator C315 zum Nachgleich der internen Antenne ist nur bei Modulen vom Typ ID CPR.M02.VP/AB-B und ID CPR.M02.VP/AB-C bestückt. FEIG ELECTRONIC GmbH Montage 50,0 44,0 V1 ...

Page 9

... Nur geregelte DC-Spannungen verwenden ! ** Die GND-Pins 4 und 9 sind auf dem Readermodul direkt miteinander verbunden Tabelle 3.2-1: Belegung der Anschlussstiftleiste X1 FEIG ELECTRONIC GmbH Montage Beschreibung ID CPR.M02 Datenleitung der DAT Daten-/Taktschnittstelle Taktleitung der CLK Daten-/Taktschnittstelle TxD RS232-TTL – Transmit Data GND ** RxD RS232-TTL – ...

Page 10

... Tabelle 3.2.1-1: Pinbelegung der Spannungsversorgung an X1 HINWEIS: • Eine Verpolung der Versorgungsspannung kann zur Zerstörung des Gerätes führen. • Versorgungsspannungen außerhalb der Spezifikation können zur Zerstörung des Gerä- tes führen. FEIG ELECTRONIC GmbH Montage Beschreibung Kurzzeichen ID CPR.M02 + ± ...

Page 11

... Die Übertragungsparameter der Schnittstelle können per Softwareprotokoll konfiguriert werden. Tabelle 3.2.2-2 zeigt die Standardparameter der RS232-Schnittstelle. Parameter Baudrate Anzahl der Datenbits Parität Anzahl der Stoppbits Tabelle 3.2.2-2: Standardparameter der RS232-Schnittstelle. FEIG ELECTRONIC GmbH Montage Beschreibung Kurzzeichen ID CPR.M02 TxD * RS232-TTL - Transmit Data GND ** ...

Page 12

... Die GND-Pins 4 und 9 sind auf dem Readermodul direkt miteinander verbunden Tabelle 3.2.3-1: Pinbelegung der RS232-Schnittstelle an X1 Data Clock Host CLS GND Bild 3.2.3-1: Anschluss der Daten-/Taktschnittstelle FEIG ELECTRONIC GmbH Montage Beschreibung Kurzzeichen ID CPR.M02 Datenleitung der DAT Daten-/Taktschnittstelle Taktleitung der ...

Page 13

... Antenne. Es handelt es sich hierbei um eine 2-polige Stiftleiste mit Rastermaß 2,54 mm Bild 3.2.4-1: Belegung der Stiftleiste X2 zum Anschluss einer externen Antenne X2 Pin-Nr Tabelle 3.2.4-1: Belegung der Stiftleiste X2 FEIG ELECTRONIC GmbH Montage X4 C405 X2 X2 C315 X3 Beschreibung Kurzzeichen ID CPR.M02.VP/AB-BA / -CA Signal-Anschluss der externen Signal 50Ω ...

Page 14

... Bei Bedarf kann das optionale Aufsteckmodul ID SAM.M02 auf die Stiftleisten X3 und X4 aufgesteckt werden. Das Aufsteckmodul ID SAM.M02 ist eine Einheit zur Aufnahme und Ansteuerung eines SAMs und bietet darüber zusätzliche Sicherheit für kryptographische Datenübertragung zwischen Reader und Transponder. Bild 3.2.4-1: Maßzeichnung ID CPR.M02 mit ID SAM.M02 FEIG ELECTRONIC GmbH Montage ...

Page 15

... HINWEIS: Ab Firmware-Version 1.08 kann das Signal der roten LED auf X1, Pin7 (CLS) zum Anschluß einer externen LED abgegriffen werden. Zur Strombegrenzung ist dazu ein Widerstand von Ω mindestens 470 einzusetzen. FEIG ELECTRONIC GmbH Montage Bild 3.3-1: Position der LED´s V1 und V2 Standardeinstellung • ...

Page 16

... Update" nachgelesen werden. Jumperposition Tabelle 3.4.1-1: Jumper FEIG ELECTRONIC GmbH Montage Mode Standardeinstellung : Der Reader befindet sich im normalen Betriebsmode. Aktivierung des Hardware-Bootloaders : Nach einem Reset startet die CPU des Readers seinen Hardware Bootloader und kann über diesen neu programmiert werden. J1 ...

Page 17

... Für den Abgleich der internen Antenne muß nun die Signalamplitude des 13,56 MHz-Signals mit Hilfe des Trimmkondensators C315 auf Maximum abgeglichen werden. Mit C315 Signalamplitude auf Maximum drehen ID CPR.M02 C65 Bild 3.4.3-2: Messaufbau zum Abgleich der internen Antenne FEIG ELECTRONIC GmbH Montage X4 Trimmkondensator C405: C405 NICHT VERÄNDERN !!! J1 C315 Trimmkondensator C315: ...

Page 18

... Trotz der hier beschriebenen Möglichkeit des Antennennachgleichs sollte der Abstand zwischen Reader und den umgebenden Metallflächen mindestens 3 cm betragen. Dabei sollte bedacht werden, dass sich auch andere Leiterplatten, je nach Kupferauflage, wie Metallflächen verhalten. FEIG ELECTRONIC GmbH Montage Beschriftung Maximale Minimale Kapazitä ...

Page 19

... Transponder kommen. Dabei wird vor allem der Empfang der Rückantwort des Transponders ge- stört. Beim Einbau eines ID CPR.M02 in ein anderes Gerät sollte daher auf eine möglichst saubere, störfreie Spannungsversorgung geachtet werden. FEIG ELECTRONIC GmbH Montage Seite 19 von 42 ID CPR.M02 M21001-3de-ID-B.doc ...

Page 20

... Bei der Festlegung der Position von Reader und Antenne in einem Gerät sollte dieses auf eventu- elle Störquelle in der oben angegebenen Form untersucht werden. Notfalls sind Abschirmmaß- nahmen zur Unterdrückung einer solchen Störquelle anzuwenden. FEIG ELECTRONIC GmbH Montage Seite 20 von 42 ID CPR ...

Page 21

... At the time of this printing, the antennas listed below were the only antennas approved for use with the ID CPR.M02 module. Use of other antennas must be approved by FEIG ELECTRONIC GmbH. Antennas approved: ID ISC.ANT100100; ID ISC.ANT4030 FEIG ELECTRONIC GmbH Montage FCC ID: PJMCPRM02 Seite 21 von 42 ID CPR.M02 ...

Page 22

... Schreiben) • Security Funktion (Optional) • Optische Anzeigen • Temperaturbereich • Zulassung Funk • EMV • Sicherheit FEIG ELECTRONIC GmbH Montage pol. Stiftleiste (Rastermaß 2,54 mm ± 5% Restwelligkeit: 0...250 kHz < 10 mVpp ab 250 kHz < 0,1 mVpp max. 1,5 W 13.56 MHz 250 mW ± ...

Page 23

...

Page 24

... The installation instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. ® ...

Page 25

... Retuning the internal antenna (ID CPR.M02.VP/AB-B / -C) ........................................37 8.5. Installation notes...............................................................................................................39 8.5.1. Metallic surroundings...................................................................................................39 8.5.2. EMC effects on cables.................................................................................................39 8.5.3. EMC effects from magnetic fields ................................................................................40 9. Radio Approvals 9.1. Europe (CE)........................................................................................................................41 9.2. USA (FCC) ..........................................................................................................................41 10. Technical Data FEIG ELECTRONIC GmbH Installation Contents Page CPR.M02 M21001-3de-ID-B ...

Page 26

... Works at the device and its installation have to be executed according to the national legal requirements and local prescriptions. • When working on devices the valid safety regulations must be observed. FEIG ELECTRONIC GmbH Installation Page CPR.M02 M21001-3de-ID-B.doc ...

Page 27

... Scope of delivery The following components are included: Modul Type ID CPR.M02.VP/AB Reader Module ID CPR.M02.VP/AB-B ID CPR.M02.VP/AB- Reader Module ID CPR.M02.VP/AB-BA ID CPR.M02.VP/AB Reader Module ID CPR.M02.VP/AB-C ID CPR.M02.VP/AB- Reader Module ID CPR.M02.VP/AB-CA FEIG ELECTRONIC GmbH Installation Antenna RS232-TTL Interface 4.800, 9.600, internal 19.200, 38.400, external Baud 4.800, 9.600, internal 19 ...

Page 28

... The terminal X2 for the connection of an external Antenna is equipped only with modu- les of the type ID CPR.M02.VP/AB-BA and CPR.M02.VP/AB-CA. • The trim capacitor C315 for retuning of the integrated Antenna is equipped only with modules of the type CPR.M02.VP/AB-B and CPR.M02.VP/AB-C. FEIG ELECTRONIC GmbH Installation 50,0 44,0 V1 ...

Page 29

... Use only regulated DC power supplies ! ** GND-Pins 4 and 9 are to be connected directly to each other on the Reader Module Table 3.2-1: Pin assignments for Terminal X1 FEIG ELECTRONIC GmbH Installation Description ID CPR.M02 DAT Data line for the data/clock interface CLK Clock line for the data/clock interface TxD RS232-TTL – ...

Page 30

... GND-Pins 4 and 9 are to be connected directly to each other on the Reader Module Table 3.2.1-1: Pin assignments for X1 NOTE: • Reversing the polarity of the supply voltage may destroy the device. • Supply voltages outside the specifications may destroy the device. FEIG ELECTRONIC GmbH Installation Description Function ID CPR.M02 + ± 5% ...

Page 31

... The transmission parameters for the interface can be software-configured. Table 3.2.2-2 shows the standard parameters for the RS232 interface. Parameter Baud rate No. of data bits Parity No. of stop bits Table 3.2.2-2: Standard parameters of the RS232 interface. FEIG ELECTRONIC GmbH Installation Description Function ID CPR.M02 TxD * RS232-TTL - Transmit Data GND ** ...

Page 32

... Reader Module Table 3.2.3-1: Pin configuration for the RS232 interface on Terminal X1 Data Clock Host CLS GND Fig. 3.2.3-1: Connecting the data/clock interface FEIG ELECTRONIC GmbH Installation Description Function ID CPR.M02 Data line for the data/clock in- DAT terface Clock line for the data/clock ...

Page 33

... Fig. 3.2.4-1 and Table 3.2.4-1 shows the pin assignments for Terminal X2 for the connection of the external antenna. The pin connector has a pin spacing of 2.54mm Fig. 3.2.4-1: Pin assignment of Terminal X2 X2 Pin no Table 3.2.4-1: Pin assignment of Terminal X2 FEIG ELECTRONIC GmbH Installation C405 Signal 1 X2 GND 2 X2 C315 Description Function ID CPR.M02.VP/AB-BA / -CA Signal pin of the external 50Ω- ...

Page 34

... If needed, the optional device ID SAM.M02 can be connected to terminals X3 and X4. The ID SAM.M02 is a module for connecting and driving an additional SAM and provides security by using cryptographic data transmission between the reader and transponder. Fig. 3.2.4-1: Dimensions of ID CPR.M02 with ID SAM.M02 FEIG ELECTRONIC GmbH Installation V1 V2 ...

Page 35

... V1 Green V2 Red Table 3.3-1: Standard setting for the LEDs NOTE: Up from Firmware-Version 1.08 the function of the red LED is connected to X1, Pin7 (CLS). For current limitation an additional resistor with 470 FEIG ELECTRONIC GmbH Installation Fig. 3.3-1: Position of LEDs V1 and V2 Standard setting • Flashes 4x after a reset. ...

Page 36

... For additional information about programming the reader, see the corresponding Application Note „Firmware Update“. Jumper position Table 3.4.1-1: Jumper J1 X1 FEIG ELECTRONIC GmbH Installation Mode Standard setting : The reader is in normal operating mode. Activation of the hardware bootloader: After a reset the reader’s CPU starts its hardware bootloader, which can then be used for new pro- gramming ...

Page 37

... To tune the internal antenna, now set the signal amplitude of the 13.56 MHz signal to maximum using trim capacitor C315. Turn C315 to set amplitude to maximum ID CPR.M02 C65 Fig. 3.4.3-2: Configuration for tuning the internal antenna FEIG ELECTRONIC GmbH Installation Trim capacitor C405: DO NOT CHANGE !!! C405 J1 ...

Page 38

... Notwithstanding the possibility of retuning the antenna as described here, the distance between the reader and the surrounding metal surfaces must be at least 3 cm. Note that even other circuit boards may act like metal objects depending on how much copper they contain. FEIG ELECTRONIC GmbH Installation Labeling Beschriftung ...

Page 39

... In spite of the internal EMC filters inside the reader, high levels of noise on the supply voltage can result in impairment of the communication between the reader and transponder. When installing an ID CPR.M02 into another device, be sure therefore that a clean, noise-free power supply is used. FEIG ELECTRONIC GmbH Installation Page CPR.M02 ...

Page 40

... Sources of such magnetic interference fields include coils within a primary or secondary switching power supply. When determining the position of the reader and antenna within a device, check the device for any possible sources of interference as described above. If necessary, use shielding to suppress such interference. FEIG ELECTRONIC GmbH Installation Page CPR.M02 M21001-3de-ID-B.doc ...

Page 41

... This device contains transmitter module FCC ID PJMCPRM02 At the time of this printing, the antennas listed below were the only antennas approved for use with the ID CPR.M02 module. Use of other antennas must be approved by FEIG ELECTRONIC GmbH. Antennas approved: ID ISC.ANT100100; ID ISC.ANT4030 FEIG ELECTRONIC GmbH Installation FCC ID: PJMCPRM02 Page CPR.M02 ...

Page 42

... Security Function (optional) • Optical Indicators • Temperature Range • Radio Approval • EMC • Safety FEIG ELECTRONIC GmbH Installation pol. Pin-Connector (grid dim. 2,54 mm ± 5% ripple 0...250 kHz < 10 mVpp ab 250 kHz < 0,1 mVpp max. 1,5 W 13.56 MHz 250 mW ± Internal External (separate 2 pol ...