R5F61665N50FPV Renesas Electronics America, R5F61665N50FPV Datasheet - Page 917

MCU FLASH 512K ROM 144-LQFP

R5F61665N50FPV

Manufacturer Part Number
R5F61665N50FPV
Description
MCU FLASH 512K ROM 144-LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8SX/1600r
Datasheet

Specifications of R5F61665N50FPV

Core Processor
H8SX
Core Size
16/32-Bit
Speed
50MHz
Connectivity
EBI/EMI, I²C, IrDA, SCI, SmartCard, USB
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
92
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
40K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R5F61665N50FPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Bit
6
5
Bit Name
RDRF
ORER
Initial
Value
0
0
R/W
R/(W)* Receive Data Register Full
R/(W)* Overrun Error
Description
Indicates whether receive data is stored in RDR.
[Setting condition]
[Clearing conditions]
The RDRF flag is not affected and retains its previous
value when the RE bit in SCR is cleared to 0.
Note that when the next serial reception is completed
while the RDRF flag is being set to 1, an overrun error
occurs and the received data is lost.
Indicates that an overrun error has occurred during
reception and the reception ends abnormally.
[Setting condition]
[Clearing condition]
Section 19 Serial Communication Interface (SCI, IrDA, CRC)
When serial reception ends normally and receive data
is transferred from RSR to RDR
When 0 is written to RDRF after reading RDRF = 1
(When the CPU is used to clear this flag by writing 0
while the corresponding interrupt is enabled, be sure
to read the flag after writing 0 to it.)
When an RXI interrupt request is issued allowing
DMAC or DTC to read data from RDR
When the next serial reception is completed while
RDRF = 1
In RDR, receive data prior to an overrun error
occurrence is retained, but data received after the
overrun error occurrence is lost. When the ORER flag
is set to 1, subsequent serial reception cannot be
performed. Note that, in clocked synchronous mode,
serial transmission also cannot continue.
When 0 is written to ORER after reading ORER = 1
(When the CPU is used to clear this flag by writing 0
while the corresponding interrupt is enabled, be sure
to read the flag after writing 0 to it.)
Even when the RE bit in SCR is cleared, the ORER
flag is not affected and retains its previous value.
Rev. 2.00 Oct. 21, 2009 Page 883 of 1454
REJ09B0498-0200

Related parts for R5F61665N50FPV