R5F61665N50FPV Renesas Electronics America, R5F61665N50FPV Datasheet - Page 1230

MCU FLASH 512K ROM 144-LQFP

R5F61665N50FPV

Manufacturer Part Number
R5F61665N50FPV
Description
MCU FLASH 512K ROM 144-LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8SX/1600r
Datasheet

Specifications of R5F61665N50FPV

Core Processor
H8SX
Core Size
16/32-Bit
Speed
50MHz
Connectivity
EBI/EMI, I²C, IrDA, SCI, SmartCard, USB
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
92
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
40K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R5F61665N50FPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 25 Flash Memory
Error Response
• Error response, H'BF, (one byte): Error response to selection of new bit rate
• ERROR: (one byte): Error code
(4)
The methods for checking of receive data are listed below.
1. Input frequency
2. Multiplication ratio
3. Operating frequency error
Rev. 2.00 Oct. 21, 2009 Page 1196 of 1454
REJ09B0498-0200
The received value of the input frequency is checked to ensure that it is within the range of
minimum to maximum frequencies which matches the clock modes of the specified device.
When the value is out of this range, an input-frequency error is generated.
The received value of the multiplication ratio or division ratio is checked to ensure that it
matches the clock modes of the specified device. When the value is out of this range, an input-
frequency error is generated.
Operating frequency is calculated from the received value of the input frequency and the
multiplication or division ratio. The input frequency is input to the LSI and the LSI is operated
at the operating frequency. The expression is given below.
The calculated operating frequency should be checked to ensure that it is within the range of
minimum to maximum frequencies which are available with the clock modes of the specified
device. When it is out of this range, an operating frequency error is generated.
Receive Data Check
Operating frequency = Input frequency × Multiplication ratio, or
Operating frequency = Input frequency ÷ Division ratio
H'11: Sum checking error
H'24: Bit-rate selection error
H'25: Error in input frequency
H'26: Multiplication-ratio error
H'27: Operating frequency error
H'BF
The rate is not available.
This input frequency is not within the specified range.
The ratio does not match an available ratio.
The frequency is not within the specified range.
ERROR

Related parts for R5F61665N50FPV