TMP86FS28DFG(JZ) Toshiba, TMP86FS28DFG(JZ) Datasheet - Page 199

IC MCU 8BIT FLASH 60KB 80-LQFP

TMP86FS28DFG(JZ)

Manufacturer Part Number
TMP86FS28DFG(JZ)
Description
IC MCU 8BIT FLASH 60KB 80-LQFP
Manufacturer
Toshiba
Series
TLCS-870/Cr
Datasheet

Specifications of TMP86FS28DFG(JZ)

Core Processor
870/C
Core Size
8-Bit
Speed
16MHz
Connectivity
SIO, UART/USART
Peripherals
LCD, PWM, WDT
Number Of I /o
62
Program Memory Size
60KB (60K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
80-LQFP
Processor Series
TLCS-870
Core
870/C
Data Bus Width
8 bit
Data Ram Size
2 KB
Interface Type
SIO, UART
Maximum Clock Frequency
16 MHz
Number Of Programmable I/os
62
Number Of Timers
6
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Development Tools By Supplier
BM1040R0A, BMP86A100010A, BMP86A100010B, BMP86A200010B, BMP86A200020A, BMP86A300010A, BMP86A300020A, BMP86A300030A, SW89CN0-ZCC, SW00MN0-ZCC
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 8 Channel
For Use With
BM1401W0A-G - FLASH WRITER ON-BOARD PROGRAMTMP89C900XBG - EMULATION CHIP TMP89F LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
TMP86FS28DFGJZ

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMP86FS28DFG(JZ)
Manufacturer:
Toshiba
Quantity:
10 000
Example :After selecting the conversion time 19.5 µs at 16 MHz and the analog input channel AIN3 pin, perform AD con-
14.4 STOP/SLOW Modes during AD Conversion
is suspended and the AD converter is initialized (ADCCR1 and ADCCR2 are initialized to initial value). Also, the
conversion result is indeterminate. (Conversion results up to the previous operation are cleared, so be sure to read
the conversion results before entering standby mode (STOP or SLOW mode).) When restored from standby mode
(STOP or SLOW mode), AD conversion is not automatically restarted, so it is necessary to restart AD conversion.
Note that since the analog reference voltage is automatically disconnected, there is no possibility of current flowing
into the analog reference voltage.
When standby mode (STOP or SLOW mode) is entered forcibly during AD conversion, the AD convert operation
version once. After checking EOCF, read the converted value, store the lower 2 bits in address 0009EH nd store
the upper 8 bits in address 0009FH in RAM. The operation mode is software start mode.
SLOOP :
: (port setting)
:
LD
LD
SET
TEST
JRS
LD
LD
LD
LD
:
:
(ADCCR1) , 00100011B
(ADCCR2) , 11011000B
(ADCCR1) . 7
(ADCDR2) . 5
T, SLOOP
A , (ADCDR2)
(9EH) , A
A , (ADCDR1)
(9FH), A
Page 187
;Set port register approrriately before setting AD
converter registers.
(Refer to section I/O port in details)
; Select AIN3
;Select conversion time(312/fc) and operation
mode
; ADRS = 1(AD conversion start)
; EOCF= 1 ?
; Read result data
; Read result data
TMP86FS28DFG