ATMEGA328-MU Atmel, ATMEGA328-MU Datasheet - Page 26

no-image

ATMEGA328-MU

Manufacturer Part Number
ATMEGA328-MU
Description
IC MCU AVR 32K FLASH 32QFN
Manufacturer
Atmel
Series
AVR® ATmegar
Datasheets

Specifications of ATMEGA328-MU

Core Processor
AVR
Core Size
8-Bit
Speed
20MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
23
Program Memory Size
32KB (16K x 16)
Program Memory Type
FLASH
Eeprom Size
1K x 8
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
32-VQFN Exposed Pad, 32-HVQFN, 32-SQFN, 32-DHVQFN
Processor Series
ATMEGA32x
Core
AVR
Data Bus Width
8 bit
Data Ram Size
2 KB
Interface Type
2-Wire, SPI, USART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
23
Number Of Timers
3
Operating Supply Voltage
1.8 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 8 Channel
Operating Temperature Range
- 40 C to + 85 C
Processor To Be Evaluated
ATMEGA328
Supply Current (max)
0.2 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
8. System Clock and Clock Options
8.1
8.1.1
8.1.2
8271C–AVR–08/10
Clock Systems and their Distribution
CPU Clock – clk
I/O Clock – clk
I/O
Figure 8-1
need not be active at a given time. In order to reduce power consumption, the clocks to modules
not being used can be halted by using different sleep modes, as described in
ment and Sleep Modes” on page
Figure 8-1.
The CPU clock is routed to parts of the system concerned with operation of the AVR core.
Examples of such modules are the General Purpose Register File, the Status Register and the
data memory holding the Stack Pointer. Halting the CPU clock inhibits the core from performing
general operations and calculations.
The I/O clock is used by the majority of the I/O modules, like Timer/Counters, SPI, and USART.
The I/O clock is also used by the External Interrupt module, but note that start condition detec-
tion in the USI module is carried out asynchronously when clk
recognition in all sleep modes.
Note:
ATmega48A/48PA/88A/88PA/168A/168PA/328/328
CPU
Note that if a level triggered interrupt is used for wake-up from Power-down, the required level
must be held long enough for the MCU to complete the wake-up to trigger the level interrupt. If the
level disappears before the end of the Start-up Time, the MCU will still wake up, but no interrupt
will be generated. The start-up time is defined by the SUT and CKSEL Fuses as described in
”System Clock and Clock Options” on page
Asynchronous
Timer/Counter
Timer/Counter
Oscillator
presents the principal clock systems in the AVR and their distribution. All of the clocks
Clock Distribution
General I/O
Modules
External Clock
clk
clk
ASY
I/O
39. The clock systems are detailed below.
System Clock
Control Unit
AVR Clock
Multiplexer
Prescaler
Clock
ADC
clk
Source clock
Oscillator
ADC
Crystal
26.
CPU Core
clk
clk
Reset Logic
CPU
FLASH
Crystal Oscillator
Watchdog clock
Low-frequency
Watchdog Timer
RAM
I/O
Watchdog
Oscillator
is halted, TWI address
Calibrated RC
”Power Manage-
Flash and
EEPROM
Oscillator
26