ixi848 IXYS Corporation, ixi848 Datasheet

no-image

ixi848

Manufacturer Part Number
ixi848
Description
High-side Current Monitor
Manufacturer
IXYS Corporation
Datasheet
Features:
• High-Side Current Sense Amplifier
• 2.7V to 40V Input Range
• 0.7% Typical Full Scale Accuracy
• Scalable Output Voltage
• SOIC Package
Applications:
• Power Management Systems
• Smart Battery Packs
• Battery Chargers
• Battery Powered Portable Equipment
• DC Motor Control
IXI848 Functional Block Diagram and
General Application Circuit
Copyright © IXYS CORPORATION 2005
4
IN
IXYS
10R
40R
R
R
R
G
G
Rs
-
1
+
GND
5
3
2
8
R10
R50
VOUT
LOAD
High-Side Current Monitor
IXI848
IL
Zm
LOAD
General Description
IXI848 SOIC PIN Configuration
Ordering Information
The IXI848 is a precision high side current sense
monitor. High side power-line monitoring offers the
advantage of allowing the ground plane to remain
undisturbed when sensing load currents.
An external sense resistor sets the range of the
amplified
voltage. The output voltage is amplified by a
selectable fixed gain of either 10 or 50. With an
input voltage range up to 40V, and output gain of up
to 50, the IXI848 is designed to address a wide
variety of current sense applications.
The IXI848 operates over a temperature range of
-40°C to +85°C. The IXI848 is available in an 8-
Lead SOIC package.
Part No.
IXI848S1
XI848S1T/R
VOUT
GND
ground-referenced
R10
IN
Description
High Side Current
Sense Monitor
1
2
3
4
SOIC-8
Package Quantity
SOIC-8
SOIC-8
8
7
6
5
output
R50
N/C
N/C
LOAD
98
2500 (T&R)
monitoring
(Tube)
06/29/05

Related parts for ixi848

ixi848 Summary of contents

Page 1

... IXI848 is designed to address a wide variety of current sense applications. The IXI848 operates over a temperature range of -40°C to +85°C. The IXI848 is available Lead SOIC package. IXI848 SOIC PIN Configuration LOAD ...

Page 2

... Storage Temp Range Lead Temperature (Soldering, 10 sec) ESD Warning ESD (electrostatic discharge) sensitive device. Although the IXI848 feature proprietary ESD protection circuitry, permanent damage may be sustained if subjected to high energy electrostatic discharges. Proper ESD precautions are recommended to avoid performance degradation or loss of functionality. ...

Page 3

... The IXI848 can be configured to measure a wide selection of currents by using different R values. Some common values for typical operation of the IXI848 are listed in the following table. Full-Scale I ( The amplifier 0. ...

Page 4

... Fig 8. Large Signal Transient Response 50X 4 .080 .075 .070 .065 .060 .055 .050 -40 - (°C) Fig 4. Supply Current vs. Temperature Gain=10 C =8pF Vin=12V L Vsense Vout 2uS/Div Gain=50 C =8pF Vin=12V L Vsense Vout 2V/Div 10uS/Div IXI848 Vin=20V 85 100mV 6mV 1V 0.06V 100mV 6mV 5v 0.3V 06/29/05 ...

Page 5

... Except as set forth in IXYS’ Standard Terms and Conditions of Sale, IXYS Corporation assumes no liability whatsoever, and disclaims any expressed or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right . www.ixys.com 8-LEAD SOIC 5 IXI848 06/29/05 ...