G6K-2F-Y OMRON [Omron Electronics LLC], G6K-2F-Y Datasheet
G6K-2F-Y
Available stocks
Related parts for G6K-2F-Y
G6K-2F-Y Summary of contents
Page 1
... Note: This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions. Model Non-latching Non-latching 2.54 mm spacing 3.2 mm coil-contact terminal spacing G6K-2F G6K-2F-Y G6K-2G G6K-2G-Y G6K-2P G6K-2P-Y Resistive load (cosφ=1) 0 125 VAC VDC Ag (Au clad) ...
Page 2
... Coil Data G6K- 2.5 mm coil-contact terminal spacing, standard, non-latching (G6K-2F, G6K-2G, G6K-2P) G6K- 3.2 mm coil-contact terminal spacing, non-latching (G6K-2F-Y, G6K-2G-Y, G6K-2P-Y) Rated voltage Rated current Coil resistance (VDC) (mA) (Ω) 3 33.0 91 4.5 23.2 194 5 21.1 237 6 17.6 341 9 11.3 795 12 9.1 1,315 24 4.6 5,220 G6KU- 3.2 mm spacing, single coil latching (G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y) ...
Page 3
... Operate voltage Release voltage Ambient temperature (°C) Electrical Service Life (with Must Operate and Must Release Voltage) (See note.) G6K-2G (F/P), G6K-2G (F/P)-Y Sample: G6K-2G Number of Relays: 10 Test conditions resistive load at 30 VDC with an operation rate of 50% Switching frequency: 1,800 operations/h Must operate ...
Page 4
... Contact Reliability Test (See note.) G6K-2G (F/P), G6K-2G (F/P)-Y NO Sample: G6K-2G contact Number of Relays Test conditions resistive load at contact 10 mVDC with an operation rate Switching frequency: 7,200 operations/h 3 Operating frequency (x10 operations) Note 1: The test was conducted at an ambient temperature of 23°C. ...
Page 5
... Note: Each value has a tolerance of ±0.3 mm. G6K-2G Note: Each value has a tolerance of ±0.3 mm. G6K-2P Note: Each value has a tolerance of ±0.3 mm. Must Operate and Must Release Bounce Time Distribution (See note.) G6K-2G (F/P) , G6K-2G (F/P)-Y Must operate bounce time Must release bounce time Sample: G6K-2G Number of Relays: 50 Time (ms) ...
Page 6
... G6K-2F-Y Note: Each value has a tolerance of ±0.3 mm. G6K-2G-Y Note: Each value has a tolerance of ±0.3 mm. G6K-2P-Y Note: Each value has a tolerance of ±0.3 mm. G6KU-2F-Y Note: Each value has a tolerance of ±0.3 mm. G6KU-2G-Y Note: Each value has a tolerance of ±0.3 mm. G6KU-2P-Y Note: Each value has a tolerance of ±0.3 mm. ...
Page 7
... Direction of Relay Insertion Top tape (cover tape) Carrier tape Emboss tape 2. Reel Dimensions Stopper (green) 3. Carrier Tape Dimensions G6K-2F, G6K-2F-Y, G6KU-2F-Y Orientation mark Pulling direction G6K-2G, G6K-2G-Y, G6KU-2G-Y 50 pcs per anti-static tube 900 pcs per reel 2 reels per box Order in box multiples ...
Page 8
... During automatic insertion of Relays, make sure to set the securing force of each claw to the following so that the Relays characteristics will be maintained. Direction A: 1.96 N Direction B: 4.90 N Direction C: 1.96 N G6K 74 Low Signal Relay (2) IRS Method (Mounting Solder: Lead-free) Upper surface of case (peak): 255˚C max. ...
Page 9
... Be sure to keep the proper distance between adjacent Relays as shown below to insure formation of good solder joints. G6K- min. G6K-2F 2.7 mm min. Two or more Relays may be mounted as closely as desired with the short sides of the Relays facing each other. G6K 75 Low Signal Relay ...
Page 10
... MEMO G6K 76 Low Signal Relay ...
Page 11
... Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. Low Signal Relay G6K ...
Page 12
... E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 06/09 Cat. No. X301-E-1 G6K Low Signal Relay 2. Programmable Products. Seller shall not be responsible for the user's pro- gramming of a programmable product, or any consequence thereof. 3. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a war- ranty ...