f75375 Feature Integration Technology Inc., f75375 Datasheet - Page 27
f75375
Manufacturer Part Number
f75375
Description
Fintek Hardware Monitor Ic Datasheet
Manufacturer
Feature Integration Technology Inc.
Datasheet
1.F75375.pdf
(55 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
f75375SG
Manufacturer:
FINTEK
Quantity:
20 000
7.12
Power on default: 00h
FAN_FAULT/VOLT_FAULT/OVT ENABLE Register Index 35h
7-4
Bit
3
2
1
0
7
6
5
4
3
2
1
Fintek
EN_F2_FAULT
EN_ F1_FAULT
EN_T2_OVT
EN_T1_OVT
EN_V3_FAULT
EN_V2_FAULT
EN_V1_FAULT
Reserved
STS_NZ_FAN2
STS_NZ_FAN1
STS_TAR_FAN2
STS_TAR_FAN1
Name
Attribute
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
A one indicates fan2’s PWMOUT duty-cycle is above (RAISE_DUTY
A one indicates fan1’s PWMOUT duty-cycle is above (RAISE_DUTY
A one indicates fan2 reading count is over then fan2 expect count,
and the PWMOUT2 duty cycle is full more then the FAN FAULT
TIME. Write 1 to clear this bit, write 0 will be ignored.
A one indicates fan1 reading count is over then fan1 expect count,
and the PWMOUT1 duty cycle is full more then the FAN FAULT
TIME. Write 1 to clear this bit, write 0 will be ignored.
A one enables the fan2 fault status to be indicated in pin
FAN_FUALT.
This bit is trappable. When PIN3 trapped to high at power-on, this bit
is set to 1. When PIN3 trapped to low at power-on, this bit is set to 0.
A one enables the fan1 fault status to be indicated in pin
FAN_FUALT.
This bit is trappable. When PIN3 trapped to high at power-on, this bit
is set to 1. When PIN3 trapped to low at power-on, this bit is set to 0.
A one enables the VT2 fault status to be indicated in pin OVT.
This bit is trappable. When PIN3 trapped to high at power-on, this bit
is set to 1. When PIN3 trapped to low at power-on, this bit is set to 0.
A one enables the VT1 fault status to be indicated in pin OVT.
This bit is trappable. When PIN3 trapped to high at power-on, this bit
is set to 1. When PIN3 trapped to low at power-on, this bit is set to 0.
A one enables the V3 fault status to be indicated in pin VOLT_FUALT
pin.
A one enables the V2 fault status to be indicated in pin VOLT
_FUALT.
A one enables the V1 fault status to be indicated in pin VOLT
_FUALT.
+ 5) and the current FAN speed is 0 ( ie. Fan Count = FFFFh).
+ 5) and the current FAN speed is 0 ( ie. Fan Count = FFFFh).
21
Feature Integration Technology Inc.
Description
F75375S/F75375SG
July 2007
V0.26P