l4969 STMicroelectronics, l4969 Datasheet - Page 12

no-image

l4969

Manufacturer Part Number
l4969
Description
System Voltage Regulator With Fault Tolerant Low Speed Can-transceiver
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
L4969
Manufacturer:
ST
0
Part Number:
l4969PD
Manufacturer:
ST
0
Part Number:
l4969UR
Manufacturer:
HAT
Quantity:
1 592
Part Number:
l4969UR
Manufacturer:
ST
0
Part Number:
l4969UR.
Manufacturer:
ST
0
Part Number:
l4969URD
Manufacturer:
ST
Quantity:
20 000
Part Number:
l4969URD.
Manufacturer:
ST
0
Part Number:
l4969URTR
Manufacturer:
ST
Quantity:
20 000
L4969
1.3.2 Negligible Errors
1.3.2.1 Transmitter
Error I and II (CANH or CANL interrupted but still tied to termination)
Error IV and VIII (CANH or CANL permanently dominant by short circuit)
In all cases above data can still be transmitted in differential mode.
1.3.2.2 Receiver
Error I and II (CANH or CANL interrupted but still tied to termination)
Error V and IX (CANH or CANL permanently recessive by short circuit)
In all cases above data can still be received in differential mode.
1.3.3
Problematic Errors
1.3.3.1 Transmitter
Error III and VI (CANH or CANL show overvoltage condition by short circuit)
Data is transmitted using the remaining dataline (single wire)
1.3.3.2 Receiver
Error III and VI (CANH or CANL show overvoltage condition by short circuit)
Data is received using the remaining dataline (single wire)
1.3.4 Severe Errors
1.3.4.1 Transmitter
Error V and IX (CANH or CANL permanently recessive by short circuit)
Data is transmitted on the remaining dataline after short circuit detection
Error VII (CANH is shorted to CANL)
Data is transmitted on CANH or CANL after overcurrent was detected
Error X (attempt to transmit more than 10 successive dominant bits (at lowest bitrate specified)
Transmission is terminated (fail safe)
1.3.4.2 Receiver
Error VII (CANH is shorted to CANL)
Data is received on CANH or CANL after detection of permanent dominant state
Error IV and VIII (CANH or CANL permanently dominant by short circuit)
Data is received on CANH or CANL after short circuit was detected
Error X (reception of a sequence of dominant bits, violating the protocol rules)
Data is received normally, error is detected by protocol-unit
The error conditions is signaled issuing an error flag inside a dedicated register which is readable by the C
through the serial interface. The information of the error type (I through X) is also stored into this register.
12/34